How to Read an ECG: The Complete System
ECG interpretation is not pattern matching — it is systematic electrophysiology. Learn the 5-step method used by emergency physicians and cardiologists worldwide.
Heart Rate Calculation
Always determine the ventricular rate first before examining morphology.
The 300 Method (Regular Rhythms)
Count the number of large boxes between two consecutive R waves:
The 10-Second / 6-Second Rule (Irregular)
For irregular rhythms like Atrial Fibrillation, count the number of QRS complexes on a 10-second rhythm strip and multiply by 6.
Rhythm & Origin
Is the rhythm regular or irregular? Is it sinus?
- Are P waves present? Upright in Lead II and biphasic/inverted in aVR?
- Is every P followed by a QRS? Confirms 1:1 AV nodal conduction.
- Is the R-R interval constant? If irregularly irregular without distinct P waves, think Atrial Fibrillation.
Cardiac Axis
The mean electrical vector of ventricular depolarization in the frontal plane.
Lead I positive (↑), aVF positive (↑). Vector between -30° and +90°.
Lead I positive (↑), aVF negative (↓). Look at Lead II: if II is negative, axis is < -30° (LVH, LBBB, LAFB).
Lead I negative (↓), aVF positive (↑). Vector > +90° (RVH, PE, LPFB, lateral MI).
Lead I negative (↓), aVF negative (↓). Vector -90° to 180° (VTach, severe hyperkalemia).
Hypertrophy & Enlargement
Check chamber dilation and ventricular wall thickening.
Left Ventricular Hypertrophy (LVH) — Sokolow-Lyon Criteria
S in V1 + R in V5 (or V6) > 35 mm (3.5 mV)
Ischemia, Injury & Infarction
Evaluate the ST segment, T wave, and pathological Q waves in contiguous vascular leads.
Leads II, III, aVF
Leads V1, V2
Leads V3, V4
Leads I, aVL, V5, V6